xtalk_threshold#

property SimulationConfigurationAc.xtalk_threshold[source]#

Return the value for Siwave cross talk threshold. THis value specifies the distance for the solver to consider lines coupled during the cross-section computation. Decreasing the value below -60dB can potentially cause solver failure.

Returns:
flot
Value of cross-talk threshold.